Motor circuit calculator

Checks motor-circuit values using the full-load current, protection percentage and other values you enter from the electrical code adopted in your jurisdiction.

Your job

Used for the NEMA starter size.

Read it from the applicable motor full-load-current table in the electrical code adopted in your jurisdiction, for your motor type, rating and voltage. Not supplied by this calculator. 0 means not entered yet.

Leave at 0 to size the conductor from the code book value. Overload protection must be set from the nameplate, so no overload figure is shown without it.

Only labels the result. The percentage below is the one that counts.

Read it from the applicable motor-protection table in the electrical code adopted in your jurisdiction, for your protection device and motor type. Not supplied by this calculator. 0 means not entered yet.

Only used to price the Teck90 cable. It does not set any ampacity.

Read from the code book ampacity table for the conductor, in the column for the termination temperature chosen below. If you enter it, the result is checked against 125% of the full-load current. Leave at 0 to skip the check.

Defaults to 60 °C. Choose 75 °C only when the equipment is marked for 75 °C conductors. The conductor ampacity at this temperature limits the result.

Used for the Teck90 cable takeoff.

Answer

Full-load current
Enter the full-load current
Minimum conductor ampacity
n/a
Your conductor
not checked
Overload setting
Enter the nameplate current
Maximum breaker or fuse
Enter the code book percentage
NEMA starter size
Size 0
Disconnect
n/a
  • Enter the full-load current from your code book motor table (or the nameplate current) to size the circuit.
  • No nameplate current entered, so no overload setting is shown. Overload protection is set from the motor nameplate current, not the code book value. Enter the nameplate current to see it.
  • Enter the code book full-load current and the maximum overcurrent percentage to see the largest breaker or fuse.

Method: Full-load current and the maximum overcurrent percentage are typed by the user from the applicable motor tables in their adopted electrical code; this calculator does the arithmetic only; Motor conductor, overload and branch-circuit-protection requirements must be confirmed against the electrical code adopted in the project jurisdiction; NEMA ICS 2 starter horsepower ratings are used for starter size selection; confirm motor disconnect sizing requirements against the electrical code adopted in the project jurisdiction; Check against the CEC edition and amendments your province adopts; confirm with the authority having jurisdiction.

Estimating aid based on a summary of the CEC. Provinces adopt different editions and amendments. Confirm with the authority having jurisdiction, and the engineer of record where one is involved.

Priced takeoff

  • Motor starter, NEMA size 1, with overload$2,038.311 ea at $2,038.313 h
Materials
$2,038.31
Labour, 3 h at $118.00
$354.00
Your cost, before markup and tax
$2,392.31

Reference prices are dated baselines (2026-11) for Ontario. Confirm them with your supplier. In TradeQuote PRO your own saved prices replace these.

How it works

You enter 11 inputs. The calculator returns the quantities, rounds them up the way the material is sold, and lists the takeoff so it can be priced.

  • Motor rating. Used for the NEMA starter size.
  • Supply.
  • Full-load current from the code book motor table (A). Read it from the applicable motor full-load-current table in the electrical code adopted in your jurisdiction, for your motor type, rating and voltage. Not supplied by this calculator. 0 means not entered yet.
  • Nameplate full-load current (optional) (A). Leave at 0 to size the conductor from the code book value. Overload protection must be set from the nameplate, so no overload figure is shown without it.
  • Service factor 1.15 or more, or temperature rise 40 °C or less. Select the condition that applies to the motor nameplate. Confirm the permitted overload setting against the motor requirements in the electrical code adopted in your jurisdiction.
  • Branch-circuit protection device. Only labels the result. The percentage below is the one that counts.
  • Maximum overcurrent percentage for that device (%). Read it from the applicable motor-protection table in the electrical code adopted in your jurisdiction, for your protection device and motor type. Not supplied by this calculator. 0 means not entered yet.
  • Conductor size for pricing (optional). Only used to price the Teck90 cable. It does not set any ampacity.
  • Ampacity of your chosen conductor (optional) (A). Read from the code book ampacity table for the conductor, in the column for the termination temperature chosen below. If you enter it, the result is checked against 125% of the full-load current. Leave at 0 to skip the check.
  • Termination temperature rating. Defaults to 60 °C. Choose 75 °C only when the equipment is marked for 75 °C conductors. The conductor ampacity at this temperature limits the result.
  • Run length to the motor (m). Used for the Teck90 cable takeoff.

The method

  • Full-load current and the maximum overcurrent percentage are typed by the user from the applicable motor tables in their adopted electrical code; this calculator does the arithmetic only
  • Motor conductor, overload and branch-circuit-protection requirements must be confirmed against the electrical code adopted in the project jurisdiction
  • NEMA ICS 2 starter horsepower ratings are used for starter size selection; confirm motor disconnect sizing requirements against the electrical code adopted in the project jurisdiction
  • Check against the CEC edition and amendments your province adopts; confirm with the authority having jurisdiction.

Check results against the code and manufacturer data that apply to your job. Prices are dated baselines to confirm with a supplier.

Add this to a real estimate in TradeQuote PRO

The takeoff lands as estimate lines with your prices, markup and tax, then becomes a proposal the client signs.

Start free trial

More electrical calculators