EV charger circuit calculator

Breaker and conductor size for a Level 2 EV charger at 125% of continuous current, voltage drop over the run, and whether the existing service has room.

Your job

The charger output, e.g. 32 A, 40 A or 48 A at 240 V.

You choose the size. It does not set any ampacity: enter the ampacity from your code book below to check it.

Read from the code book ampacity table for your conductor, material and insulation, in the column for the termination temperature chosen below. If you enter it, it is checked against 125% of the charger current. Leave at 0 to skip.

Defaults to 60 °C. Choose 75 °C only when the equipment is marked for 75 °C conductors. The conductor ampacity at this temperature limits the result.

From the dwelling load calculator, before the charger.

Answer

Breaker
50 A 2-pole (50 A at 125%)
Required conductor ampacity
50 A (125% of charger current)
Conductor chosen
not chosen
Voltage drop
choose a size
Smallest size within 3% drop
10 AWG (voltage drop only, not ampacity)
Service capacity
0 A to spare
Load management
Not needed
  • Choose a conductor size to see the voltage drop and to price the wire; the ampacity must come from your code book.
  • The charger is counted at 100% of its rating in the service calculation (Rule 8-200); the 125% applies to the branch circuit.

Method: CEC Section 86 provides the general electric-vehicle-charging context; confirm branch-circuit requirements against the electrical code adopted in the project jurisdiction; Conductor ampacity is typed by the user from their own code book; no ampacity table is built in. Voltage drop (Rule 8-102) uses resistance computed from resistivity and conductor area; Service load for a single dwelling is checked using the Rule 8-200 calculation context; confirm EV energy-management provisions against the electrical code adopted in your province; Check against the CEC edition and amendments your province adopts; confirm with the authority having jurisdiction.

Estimating aid based on a summary of the CEC. Provinces adopt different editions and amendments. Confirm with the authority having jurisdiction, and the engineer of record where one is involved.

Priced takeoff

  • Level 2 EV charger, 48 A hardwired$716.091 ea at $716.093 h
  • Breaker 50 A 2-pole$82.731 ea at $82.730.15 h
Materials
$798.82
Labour, 3.15 h at $99.00
$311.85
Your cost, before markup and tax
$1,110.67

Reference prices are dated baselines (2026-11) for Ontario. Confirm them with your supplier. In TradeQuote PRO your own saved prices replace these.

How it works

You enter 9 inputs. The calculator returns the quantities, rounds them up the way the material is sold, and lists the takeoff so it can be priced.

  • Charger rated current (A). The charger output, e.g. 32 A, 40 A or 48 A at 240 V.
  • Distance from the panel to the charger (m).
  • Conductor material.
  • Conductor size for pricing and voltage drop. You choose the size. It does not set any ampacity: enter the ampacity from your code book below to check it.
  • Ampacity of your chosen conductor (optional) (A). Read from the code book ampacity table for your conductor, material and insulation, in the column for the termination temperature chosen below. If you enter it, it is checked against 125% of the charger current. Leave at 0 to skip.
  • Termination temperature rating. Defaults to 60 °C. Choose 75 °C only when the equipment is marked for 75 °C conductors. The conductor ampacity at this temperature limits the result.
  • Existing service size (A).
  • Existing calculated load (Rule 8-200) (A). From the dwelling load calculator, before the charger.
  • Energy management system installed (EVEMS). A system that limits the charger so the service is never overloaded.

The method

  • CEC Section 86 provides the general electric-vehicle-charging context; confirm branch-circuit requirements against the electrical code adopted in the project jurisdiction
  • Conductor ampacity is typed by the user from their own code book; no ampacity table is built in. Voltage drop (Rule 8-102) uses resistance computed from resistivity and conductor area
  • Service load for a single dwelling is checked using the Rule 8-200 calculation context; confirm EV energy-management provisions against the electrical code adopted in your province
  • Check against the CEC edition and amendments your province adopts; confirm with the authority having jurisdiction.

Check results against the code and manufacturer data that apply to your job. Prices are dated baselines to confirm with a supplier.