Dwelling service load calculator

Calculated load and minimum service size for a single dwelling under CEC Rule 8-200, with the panel and meter base for the takeoff.

Your job

Use the living-area measurement method required by the electrical code adopted in your jurisdiction.

Counted at 75% when the ceiling is higher than 1.8 m.

Enter the connected electric space-heating load. Confirm the applicable demand treatment against the electrical code adopted in your jurisdiction.

Counted at 100%.

0 if there is no electric range.

Enter the EV charging load. Confirm any permitted energy-management treatment against the electrical code adopted in your jurisdiction.

Welders, pumps and similar fixed loads, counted with the dryer and water heater. Do not enter hot tubs, spas or pool heating here; use the field below.

Counted at 100% of the rating, added to the calculated load.

Answer

Minimum service
100 A at 240 V
Calculated load
24,000 W (100 A)
Living area
157.5 m²
Basic load
6,000 W
Heating and cooling
0 W
Range, water heater, EV
6,000 W
Hot tub, spa and pool heating (100%)
0 W
Other loads over 1.5 kW
2,000 W demand from 8,000 W connected
Minimum under 8-200 1) b)
24000 W
  • The Rule 8-200 1) b) minimum of 24000 W governs, so the calculated load is that minimum.

Method: CEC Rule 8-200 provides the single-dwelling load-calculation context; confirm the applicable demand factors and minimums against the edition and amendments adopted in the project jurisdiction; Living area, interlocked loads and space-heating demand treatment must be confirmed against the electrical code edition and amendments adopted in the project jurisdiction; Amperes = calculated watts / 240 V; service sizes rounded up to the next common size; Check against the CEC edition and amendments your province adopts; confirm with the authority having jurisdiction.

Estimating aid based on a summary of the CEC. Provinces adopt different editions and amendments. Confirm with the authority having jurisdiction, and the engineer of record where one is involved.

Priced takeoff

  • Loadcentre 100 A, 24/48 circuit, main breaker$159.581 ea at $159.584 h
  • Meter socket 200 A$219.171 ea at $219.172.5 h
Materials
$378.75
Labour, 6.5 h at $99.00
$643.50
Your cost, before markup and tax
$1,022.25

Reference prices are dated baselines (2026-11) for Ontario. Confirm them with your supplier. In TradeQuote PRO your own saved prices replace these.

How it works

You enter 14 inputs. The calculator returns the quantities, rounds them up the way the material is sold, and lists the takeoff so it can be priced.

  • Ground floor area (m²). Use the living-area measurement method required by the electrical code adopted in your jurisdiction.
  • Upper floor area used for living (m²).
  • Basement area (m²). Counted at 75% when the ceiling is higher than 1.8 m.
  • Basement ceiling higher than 1.8 m.
  • Electric space heating (connected) (kW). Enter the connected electric space-heating load. Confirm the applicable demand treatment against the electrical code adopted in your jurisdiction.
  • Air conditioning (kW). Counted at 100%.
  • Heating and air conditioning interlocked. When the installation qualifies for interlocked-load treatment, the calculator uses the larger load. Confirm that the installation qualifies under the electrical code adopted in your jurisdiction.
  • Electric range (kW). 0 if there is no electric range.
  • Water heater (kW).
  • Water heater is tankless. Tankless heaters count at 100%.
  • Clothes dryer (kW).
  • EV charger (kW). Enter the EV charging load. Confirm any permitted energy-management treatment against the electrical code adopted in your jurisdiction.
  • Other fixed loads over 1.5 kW each (total) (kW). Welders, pumps and similar fixed loads, counted with the dryer and water heater. Do not enter hot tubs, spas or pool heating here; use the field below.
  • Hot tub, spa and pool heating loads (total) (kW). Counted at 100% of the rating, added to the calculated load.

The method

  • CEC Rule 8-200 provides the single-dwelling load-calculation context; confirm the applicable demand factors and minimums against the edition and amendments adopted in the project jurisdiction
  • Living area, interlocked loads and space-heating demand treatment must be confirmed against the electrical code edition and amendments adopted in the project jurisdiction
  • Amperes = calculated watts / 240 V; service sizes rounded up to the next common size
  • Check against the CEC edition and amendments your province adopts; confirm with the authority having jurisdiction.

Check results against the code and manufacturer data that apply to your job. Prices are dated baselines to confirm with a supplier.